Pitch |
1.00 mm
|
0.50 mm
|
 |
|
Physical |
|
|
| Recommended Pad
Diameter (Filled Vias) |
0.60 mm |
0.30 mm |
| Minimum Pad Edge to
Edge Gap |
0.40 mm |
0.20 mm |
| Thickness
(uncompressed) |
0.25 mm |
0.13 mm |
| Hardness (shore A) |
55 |
55 |
| Tensile Strength |
0.295 kg/mm2 |
0.295 kg/mm2 |
| Elongation of Base
Elastomer |
300 % |
300 % |
| Tear Strength |
0.91 kg/mm2 |
0.91 kg/mm2 |
|
Electrical |
|
|
| Voltage Breakdown
|
1000 V |
~750 V |
| Typical Contact Resistance |
<15m W |
<25m W |
| Isolation Resistance |
>109W |
>109W |
| Current Carrying
Capability |
2 amps |
1 amp |
|
Time Domain:
Signal Delay
Risetime, thru into 50 Ω |
2 ps
30 ps
(test system
risetime)
|
2 ps
30 ps
(test system
risetime) |
|
Frequency Domain:
Insertion loss |
< 0.5 dB to 25 GHz
< 1 dB to 40 GHz |
< 0.5 dB to 25 GHz
< 1 dB to 40 GHz |
|
Equivalent Circuit
Parameters:
Inductance:
S to GND capacitance:
Transmission line: |
0.094 nH
0.023 pF
Z0=55
W
T1 = 2 (typ) ps |
0.094 nH
0.023 pF
Z0=55
W
T1
= 2 (typ) ps |
|
Reliability |
|
|
|
Temperature Cycling
(contact resistance after 315 cycles, -20
°C to +100
°C):
Gold-plated
contacts |
<1% change |
<1% change |
|
Corrosive Atmosphere
(contact resistance after 1000 hrs. with temperature-humidity cycling):
Gold-plated contacts |
<5% change |
<5% change |
|
Shock and Vibration
per EIA-540, Test Procedure FP2 and FP3: |
pass |